Water-based extinguishing
High-pressure water mistPowerful extinguishing with very little water
High-performance fire protection that uses very little water: high-pressure water mist cools the fire and deprives it of oxygen, while limiting water damage to your facilities.
- Design study and in-house engineering office
- Installation by our teams
- System maintenance
- > 35 barsSpray pressure
- < 200 µmDroplet size
- OH1 to OH3Hazard classes covered
- Stainless steelSmall-diameter pipework
Applications
For sites where water must be used sparingly
Where a traditional system would flood the premises, water mist extinguishes with very little water and preserves equipment.
-
Hotels, offices & public-access buildings
Extinguishing with water alone, compatible with the presence of the public and occupants.
-
Data centres
Little water discharged, to preserve equipment and resume operations quickly.
-
Car parks & high-rise buildings
Small-diameter stainless steel networks, suited to high-rise buildings.
-
Technical rooms
Generators, transformers and archives: rapid cooling of the fire.
Operating principle
How a water mist system works
Water is raised to more than 35 bars and then sprayed as extremely fine droplets: they absorb heat and, as they vaporise, reduce the oxygen as close to the fire as possible.
-
High-pressure pump set
The pumps raise the water to more than 35 bars and supply the network as soon as a fire is detected.
-
Control panel
It controls the start-up of the pump set and reports information to your fire safety system.
-
Small-diameter stainless steel network
Slim, corrosion-resistant pipework that is easy to integrate into an existing building.
-
Section valve
It controls the supply to the protected zone and allows it to be isolated for maintenance.
-
Mist nozzles
They break the water up into droplets of less than 200 µm that cool and smother the fire.
The benefits
Why choose high-pressure water mist
A laboratory-validated technology for OH1, OH2 and OH3 class risks.
-
01
Very low water consumption
A reduced quantity of water for high extinguishing efficiency, an advantage when the water supply is limited.
-
02
Powerful cooling
The very fine droplets quickly absorb the heat of the fire and smoke.
-
03
Limited water damage
Less water discharged means less damage to equipment and premises.
-
04
Safe for people
Extinguishing relies solely on water, with no chemical agent.
-
05
Compact footprint
Small-diameter stainless steel pipes, easy to integrate into an existing building.
-
06
Rapid return to operation
Reduced downtime after discharge thanks to limited damage.
Our projects
They entrusted us with their fire protection
A selection of systems designed and installed by our teams.
Standards and guidelines
A compliant installation
- EN 14972-1European standard for fixed water mist systems: design, installation, maintenance.
- NFPA 750International standard for the design of water mist systems.
- APSAD R2French rules for the installation and maintenance of water mist systems.
- Public-access buildingsFire safety regulations for public-access buildings.
- Bio-basedGuidance applicable to buildings made of bio-based and combustible materials.
Feasibility study
Is water mist suitable for your site?
Our engineers analyse your risk, your premises and your water supply to validate the most appropriate solution.
- Site visit and risk analysis
- Reasoned technical recommendation
- Installation cost estimate
Frequently asked questions
High-pressure water mist: your questions
Can't find your answer? Our engineering offices will call you back.
What is the difference between high-pressure and low-pressure water mist?
They are two complementary technologies. High pressure operates above 35 bars, with droplets smaller than 200 µm and very small-diameter stainless steel pipework. Low pressure operates at a pressure below 12.5 bars, with stainless steel or galvanised pipework and limited electrical requirements. Our engineering offices select the technology suited to your risk, your building and your water supply.
Is water mist dangerous to people?
No. The system uses only water: it can operate when people are present, making it a suitable solution for hotels, offices and public-access buildings.
Can water mist be installed in an existing building?
Yes. Small-diameter stainless steel pipes are easier to install than traditional networks and limit work in occupied premises. Our engineering offices can design the network from a survey or a 3D scan of your site.
Our other solutions
A technology for every risk
-
SprinklerThe benchmark in automatic protection, by an APSAD R1 certified installer
-
Low-pressure water mistThe water-saving alternative to traditional systems
-
Water and foam monitorsTargeted spraying for large volumes
-
Automatic gas extinguishingProtect your equipment without getting it wet
-
Foam extinguishingSmother flammable liquid fires and protect large volumes
-
Technical unitsCustom-built in our workshops
Your project
Let's talk about your water mist system
Describe your site and your needs: we will get back to you with an initial analysis and a cost estimate.
Contact my branchClick the photo to zoom in