Water-based extinguishing

Low-pressure water mistThe water-saving alternative to traditional systems

Low-pressure water mist is a fire protection technology that uses very fine water droplets to control or extinguish a fire while using far less water than a traditional sprinkler system.

  • Design study and in-house engineering office
  • Installation by our teams
  • System maintenance
Low-pressure water mist system, isometric view
< 12.5 barsModerate pressure
Water onlyNo chemical agent
  • < 12.5 barsOperating pressure
  • OH1 to OH3Hazard classes covered
  • Stainless or galvanised steelSmall-diameter pipework
  • Low flow rateLimited power requirement

Applications

Protection suited to many types of premises

Hotels, offices, data centres or technical rooms: low pressure protects your premises with a system that is simple to operate.

  • Hotels, offices & public-access buildings

    Water-based extinguishing, compatible with the presence of the public and occupants.

  • Data centres

    Limited water damage to sensitive equipment.

  • Car parks

    Protection for large volumes with reduced water consumption.

  • Technical rooms

    Generators, transformers and archives.

Operating principle

How a low-pressure system works

The system operates at a pressure below 12.5 bars: the nozzles produce a mist that absorbs the heat of the fire and then, as it evaporates, reduces the oxygen around the flames.

3D Revit view of a low-pressure water mist system: pump set, discharge piping, control valve station, pipework and nozzles
  1. Pump set

    The pumps supply the system at a pressure below 12.5 bars, with a limited power requirement.

  2. Discharge piping

    It carries water from the source and the pump set to the protected premises.

  3. Control valve station

    It supplies the system and enables the alarm to be raised if a fire breaks out.

  4. Stainless or galvanised steel pipework

    Small-diameter pipes installed at ceiling level, easy to integrate into existing buildings.

  5. Mist nozzles

    Distributed according to the system design, they discharge a mist generated at a low pressure of less than 12.5 bars.

The benefits

Why choose low-pressure water mist

A system tested and approved in the laboratory for OH1, OH2 and OH3 hazard classes.

  • 01

    Limited power requirement

    A moderate pressure that reduces the pumping power required.

  • 02

    Low water consumption

    Less water stored and discharged than with a traditional system.

  • 03

    Effective cooling

    The mist absorbs heat from the fire and the smoke.

  • 04

    Limited water damage

    Reduced damage to your equipment after discharge.

  • 05

    Safe for people

    Water-based extinguishing, with no chemical agent.

  • 06

    Compact footprint

    Compact stainless steel or galvanised pipework, easy to integrate.

  • 07

    Combined solution possible

    Low-pressure water mist can be combined with a sprinkler system.

  • 08

    Acceptable pressure for emergency services

    An operating pressure that is acceptable for emergency services.

Our projects

They entrusted us with their fire protection

A selection of systems designed and installed by our teams.

Low-pressure water mist
Low-pressure water mist
Low-pressure water mist

Standards and guidelines

A compliant installation

  • EN 14972-1European standard for fixed water mist systems: design, installation, maintenance.
  • NFPA 750International standard for the design of water mist systems.
  • APSAD R2French rules for the installation and maintenance of water mist systems.
  • Public-access buildingsFire safety regulations for public-access buildings.
  • Bio-basedGuidance applicable to buildings made of bio-based and combustible materials.

Feasibility study

Which protection is right for your site?

Our engineers study every protection solution suited to your risk, your building and your operating constraints.

  • Site visit and risk analysis
  • Reasoned technical recommendation
  • Installation cost estimate

Frequently asked questions

Low-pressure water mist: your questions

Can't find your answer? Our engineering offices will call you back.

Can low-pressure water mist replace a sprinkler system?

It can be an alternative for many risks, provided it is designed to a recognised standard, such as EN 14972, and approved by the project stakeholders: insurer, inspection body and authorities.

What is the difference between high-pressure and low-pressure water mist?

They are two complementary technologies. High pressure operates above 35 bars, with droplets smaller than 200 µm and very small-diameter stainless steel pipework. Low pressure operates at a pressure below 12.5 bars, with stainless steel or galvanised pipework and limited electrical requirements. Our engineering offices select the technology suited to your risk, your building and your water supply.

What maintenance is required?

Like any automatic extinguishing system, it is subject to periodic inspections: water supply, pumps, valves and nozzles. Our teams carry out these inspections under a maintenance contract.

Your project

Let's talk about your water mist system

Describe your site and your needs: we will get back to you with an initial analysis and a cost estimate.

Contact my branch