Water-based extinguishing
Low-pressure water mistThe water-saving alternative to traditional systems
Low-pressure water mist is a fire protection technology that uses very fine water droplets to control or extinguish a fire while using far less water than a traditional sprinkler system.
- Design study and in-house engineering office
- Installation by our teams
- System maintenance
- < 12.5 barsOperating pressure
- OH1 to OH3Hazard classes covered
- Stainless or galvanised steelSmall-diameter pipework
- Low flow rateLimited power requirement
Applications
Protection suited to many types of premises
Hotels, offices, data centres or technical rooms: low pressure protects your premises with a system that is simple to operate.
-
Hotels, offices & public-access buildings
Water-based extinguishing, compatible with the presence of the public and occupants.
-
Data centres
Limited water damage to sensitive equipment.
-
Car parks
Protection for large volumes with reduced water consumption.
-
Technical rooms
Generators, transformers and archives.
Operating principle
How a low-pressure system works
The system operates at a pressure below 12.5 bars: the nozzles produce a mist that absorbs the heat of the fire and then, as it evaporates, reduces the oxygen around the flames.
-
Pump set
The pumps supply the system at a pressure below 12.5 bars, with a limited power requirement.
-
Discharge piping
It carries water from the source and the pump set to the protected premises.
-
Control valve station
It supplies the system and enables the alarm to be raised if a fire breaks out.
-
Stainless or galvanised steel pipework
Small-diameter pipes installed at ceiling level, easy to integrate into existing buildings.
-
Mist nozzles
Distributed according to the system design, they discharge a mist generated at a low pressure of less than 12.5 bars.
The benefits
Why choose low-pressure water mist
A system tested and approved in the laboratory for OH1, OH2 and OH3 hazard classes.
-
01
Limited power requirement
A moderate pressure that reduces the pumping power required.
-
02
Low water consumption
Less water stored and discharged than with a traditional system.
-
03
Effective cooling
The mist absorbs heat from the fire and the smoke.
-
04
Limited water damage
Reduced damage to your equipment after discharge.
-
05
Safe for people
Water-based extinguishing, with no chemical agent.
-
06
Compact footprint
Compact stainless steel or galvanised pipework, easy to integrate.
-
07
Combined solution possible
Low-pressure water mist can be combined with a sprinkler system.
-
08
Acceptable pressure for emergency services
An operating pressure that is acceptable for emergency services.
Our projects
They entrusted us with their fire protection
A selection of systems designed and installed by our teams.
Standards and guidelines
A compliant installation
- EN 14972-1European standard for fixed water mist systems: design, installation, maintenance.
- NFPA 750International standard for the design of water mist systems.
- APSAD R2French rules for the installation and maintenance of water mist systems.
- Public-access buildingsFire safety regulations for public-access buildings.
- Bio-basedGuidance applicable to buildings made of bio-based and combustible materials.
Feasibility study
Which protection is right for your site?
Our engineers study every protection solution suited to your risk, your building and your operating constraints.
- Site visit and risk analysis
- Reasoned technical recommendation
- Installation cost estimate
Frequently asked questions
Low-pressure water mist: your questions
Can't find your answer? Our engineering offices will call you back.
Can low-pressure water mist replace a sprinkler system?
It can be an alternative for many risks, provided it is designed to a recognised standard, such as EN 14972, and approved by the project stakeholders: insurer, inspection body and authorities.
What is the difference between high-pressure and low-pressure water mist?
They are two complementary technologies. High pressure operates above 35 bars, with droplets smaller than 200 µm and very small-diameter stainless steel pipework. Low pressure operates at a pressure below 12.5 bars, with stainless steel or galvanised pipework and limited electrical requirements. Our engineering offices select the technology suited to your risk, your building and your water supply.
What maintenance is required?
Like any automatic extinguishing system, it is subject to periodic inspections: water supply, pumps, valves and nozzles. Our teams carry out these inspections under a maintenance contract.
Our other solutions
A technology for every risk
-
SprinklerThe benchmark in automatic protection, by an APSAD R1 certified installer
-
High-pressure water mistPowerful extinguishing with very little water
-
Water and foam monitorsTargeted spraying for large volumes
-
Automatic gas extinguishingProtect your equipment without getting it wet
-
Foam extinguishingSmother flammable liquid fires and protect large volumes
-
Technical unitsCustom-built in our workshops
Your project
Let's talk about your water mist system
Describe your site and your needs: we will get back to you with an initial analysis and a cost estimate.
Contact my branchClick the photo to zoom in